Catalogue photo of the Robertshaw blade, fiber optic version shown; the size is not stated.
Photo 2Photo 3360° view3D modelVideo Robertshaw Optic Blades, English Profile
AL-1413 · 2 sizes · 95mm to 113mm
The Robertshaw blade has a straight tongue with a gentle curve near the tip. It is designed to lift the epiglottis indirectly. More
- 2Sizes
- 0 to 1Blade numbers
- ISO 7376Green system
- 134 °CAutoclavable
- Prices and lead time within one working day
- Evaluation samples on request
- Certificates you can verify yourself
- Made in our own factory in Sialkot since 1981
Sizes and codes
Choose your size
Every size has its own page and its own code. Use the code when you ask for a price.
0
Robertshaw 0 · 95mm
Neonate
AL-1413-0
Example photo
1
Robertshaw 1 · 113mm
Infant
AL-1413-1
| Code | Description | Blade number | Size | Page |
|---|---|---|---|---|
| AL-1413-0 | Neonate | 0 | 95mm | Open size 0 |
| AL-1413-1 | Infant | 1 | 113mm | Open size 1 |
Overview
About the Robertshaw Optic Blades, English Profile
The Robertshaw blade has a straight tongue with a gentle curve near the tip. It is designed to lift the epiglottis indirectly. The flange is extended to the left. The blade was designed for infants and children. It may be useful for nasotracheal intubation because it allows a Magill forceps to be introduced with a minimum loss of view.
Reusable laryngoscope blade to view the larynx during tracheal intubation. The light sits in the handle and travels through the glass fiber optic light guide to the tip of the blade.
The range runs from size 0 (95mm, Neonate) to size 1 (113mm, Infant). Every size has its own code and its own page.
Size numbers are not fully standardised between makers, so compare the size in millimetres when you replace blades from another brand. Our blade size guide explains the typical patient group for each size. The choice of blade is always a clinical decision.
Sizes in this range, 95mm to 113mm
Specifications
Technical details
From our catalogue, Premium Laryngoscope Range, Volume III.
Identification
| Product | Robertshaw Optic Blades, English Profile |
|---|---|
| Product code | AL-1413 |
| Size codes | AL-1413-0 to AL-1413-1 |
| Blade numbers | 0 to 1 (2 sizes) |
| Sizes | 95mm to 113mm |
| Category | Reusable Special Blades |
| Pattern | Robertshaw, straight blade |
| Profile | English |
Light
| Light system | Fiber optic, green system |
|---|---|
| Light guide | Fiber optic light guide |
| Light source | In the handle (LED or xenon, depending on the handle) |
| LED lamp life (LED handles) | 50,000 hours |
| Continuous operation (LED handles) | 2 hours |
| Light at the blade tip (LED handles) | 8,000 to 10,000 lux |
Material and reprocessing
| Material | Stainless steel |
|---|---|
| Use | Reusable |
| Sterilisation | Autoclavable at 134 °C for 5 minutes (reusable range) |
Standard and fit
| Standard | Made to comply with ISO 7376 (reusable range) |
|---|---|
| Handle fit | Green-system handles made to ISO 7376 |
| Conventional handles | Not designed to fit (different fitting) |
Origin
| Manufacturer | Long Life Surgical Industries |
|---|---|
| Made in | Sialkot, Pakistan |
| Making laryngoscopes since | 1981 |
| Catalogue | Premium Laryngoscope Range, Volume III, page 39 |
Compatibility
Fits green-system handles
The blade is made to comply with ISO 7376, the international standard for laryngoscopes, and uses the fiber optic green-system fitting. It fits green-system handles made to ISO 7376, from us or from another maker.
It is not designed for conventional handles: a conventional blade carries a small lamp near its tip, while a green-system blade takes its light from a lamp or LED in the handle. Read ISO 7376 and the green system explained.
Handles in our green-system range
Battery Handles Fiber Optic Xenon, Stainless SteelAL-1451 · 5 sizes · See the handle
Battery Handles Fiber Optic Xenon, Brass Chrome PlatedAL-1452 · 5 sizes · See the handle
Battery Handles Fiber Optic LED, Stainless SteelAL-1453 · 5 sizes · See the handle
Battery Handles Fiber Optic LED, Brass Chrome PlatedAL-1454 · 5 sizes · See the handle
Spare part Replacement LampsAL-1455 · 4 codes · Spare part
- LED lamp life with LED handles: 50,000 hours
- Continuous operation with LED handles: 2 hours
- Light at the blade tip with LED handles: 8,000 to 10,000 lux
LED or xenon? Compare the two light sources.
Care and reprocessing
Made to be used again and again
Reusable blades are cleaned and steam sterilised between patients. Always follow the instructions for use (IFU) and your hospital's validated process.
- 01Clean the blade after each use, as described in the instructions for use (IFU).
- 02Remove the light guide if it needs to be cleaned or sterilised on its own: it can be autoclaved separately.
- 03Steam sterilise (autoclave) at 134 °C for 5 minutes.
- 04The blade is made for 2,000 to 3,000 autoclave cycles at maximum light output.
Questions
Common questions about this blade
Which sizes of the Robertshaw Optic Blades, English Profile are available?
There are 2 sizes: size 0 (Neonate, 95mm, code AL-1413-0), size 1 (Infant, 113mm, code AL-1413-1).
Which Robertshaw blade size is for a neonate, infant or child?
In the catalogue, the Robertshaw Optic Blades, English Profile has these sizes for babies and children: size 0 (Neonate, 95mm, code AL-1413-0), size 1 (Infant, 113mm, code AL-1413-1). Choosing the size for a patient is a clinical decision. Our size chart compares every length on a millimetre ruler.
How long is each Robertshaw blade size in millimetres?
In the Robertshaw Optic Blades, English Profile, size 0 is 95mm; size 1 is 113mm.
What is the Robertshaw blade, English profile?
The Robertshaw blade has a straight tongue with a gentle curve near the tip. It is designed to lift the epiglottis indirectly. The flange is extended to the left. The blade was designed for infants and children. It may be useful for nasotracheal intubation because it allows a Magill forceps to be introduced with a minimum loss of view.
Which handles fit this blade?
It is a fiber optic green-system blade, made to comply with ISO 7376, so it fits green-system handles made to ISO 7376. In our own range: Battery Handles Fiber Optic Xenon, Stainless Steel, Battery Handles Fiber Optic Xenon, Brass Chrome Plated, Battery Handles Fiber Optic LED, Stainless Steel, Battery Handles Fiber Optic LED, Brass Chrome Plated.
Does it fit a conventional laryngoscope handle?
No. Green-system (fiber optic) and conventional laryngoscopes use different fittings and light positions, so their blades and handles are not designed to work together. Use a green-system handle.
How is the blade sterilised?
It is reusable. Autoclavable at 134 °C for 5 minutes (reusable range). The light guide is removable and can be autoclaved separately. Follow the instructions for use (IFU).
Where is it made?
In our own factory in Sialkot, Pakistan. Long Life Surgical Industries has made laryngoscopes since 1981.
How do I get a price or samples?
Add it to your enquiry list, or send us the codes with quantities and your country. Our export team replies within one working day with prices and lead times. Evaluation samples are available on request.
Documents
For your file or tender
Sent with every quotation, and on request at any time.
Next steps