Shown: size 2 · 154mm
Photo 2Photo 3360° view3D modelVideo Fiber Optic Green System Disposable Blades
Miller Blades, Fiber Optic Acrylic, Metallic ECO Line
AL-1804-E · 6 sizes · 65mm to 205mm
ECO Line single-use Miller laryngoscope blade for the fiber optic green system, in metallic construction: a straight stainless steel spatula with a metal heel, and an acrylic (plastic) optical fiber light guide. There is no lamp in the blade: the light comes from the green-system handle. More
- 6Sizes
- 00 to 4Blade numbers
- ISO 7376Green system
- Single useOne patient
- Prices and lead time within one working day
- Evaluation samples on request
- Certificates you can verify yourself
- Made in our own factory in Sialkot since 1981
The whole ECO Line, from Premature to Large Adult
6 sizes, from size 00 (65mm) to size 4 (205mm). Every blade below is drawn to its length in our catalogue. Tap a blade to open its own page.
- 6sizes
- 65mmsmallest, premature
- 205mmlargest, large adult
Photos scaled to the blade lengths in our catalogue (Premium Laryngoscope Range, Volume III, page 24).
Compare
Standard or ECO Line?
The same Miller single-use blade, in two versions. Both are in our catalogue; the facts below are taken from it.
| Fact | Standard Miller Blades Fiber Optic Acrylic, Metallic |
ECO Line Miller Blades, Fiber Optic Acrylic, Metallic ECO Line |
|---|---|---|
| Product code | AL-1804 | AL-1804-E |
| Sizes | 6 sizes: 00 to 4 | 6 sizes: 00 to 4 |
| Smallest blade | Size 00, Premature, 65mm | Size 00, Premature, 65mm |
| Largest blade | Size 4, Large Adult, 205mm | Size 4, Large Adult, 205mm |
| Size codes | AL-1804-00 to AL-1804-4 | AL-1804-00E to AL-1804-4E |
| Use | Single patient use | Single patient use |
| Catalogue page | 23 | 24 |
Sizes and codes
Choose your size
Every size has its own page and its own code. Use the code when you ask for a price.
00
Miller 00 · 65mm
Premature
AL-1804-00E
0
Miller 0 · 78mm
Neonate
AL-1804-0E
1
Miller 1 · 102mm
Infant
AL-1804-1E
2
Miller 2 · 154mm
Child
AL-1804-2E
3
Miller 3 · 195mm
Medium Adult
AL-1804-3E
4
Miller 4 · 205mm
Large Adult
AL-1804-4E
| Code | Description | Blade number | Size | Page |
|---|---|---|---|---|
| AL-1804-00E | Premature | 00 | 65mm | Open size 00 |
| AL-1804-0E | Neonate | 0 | 78mm | Open size 0 |
| AL-1804-1E | Infant | 1 | 102mm | Open size 1 |
| AL-1804-2E | Child | 2 | 154mm | Open size 2 |
| AL-1804-3E | Medium Adult | 3 | 195mm | Open size 3 |
| AL-1804-4E | Large Adult | 4 | 205mm | Open size 4 |
Overview
About the Miller Blades, Fiber Optic Acrylic, Metallic ECO Line
ECO Line single-use Miller laryngoscope blade for the fiber optic green system, in metallic construction: a straight stainless steel spatula with a metal heel, and an acrylic (plastic) optical fiber light guide. There is no lamp in the blade: the light comes from the green-system handle. Supplied surgically cleaned, individually packed and labelled, latex free. Conforms to ISO 7376 and fits existing green-system handles. 6 sizes, from size 00 Premature (65mm) to size 4 (205mm).
Single-use laryngoscope blade to view the larynx during tracheal intubation, for one patient. There is no lamp in the blade: the light comes from the green-system handle and travels through the acrylic optical fiber to the blade.
The range runs from size 00 (65mm, Premature) to size 4 (205mm, Large Adult). Every size has its own code and its own page.
From our catalogue (page 16)
- Single patient use only.
- Latex free and safe in use.
- Especially very effective under emergency situations.
- Green system no direct contact of light.
- Stainless steel spatula and aluminum heel makes, practically unbreakable.
- Semi-metal blade also hold reinforcement metal hook to make it unbreakable.
- Low cost price with high quality.
- Round tip helps reduce trauma.
- Plastic optically fiber 5mm dia gives clear and maximum illumination.
- Black shrink tube on individual light guide protects light dispersion or reflection to doctor as well.
- Available in all sizes of Macintosh and Miller.
- Supplied surgically cleaned.
- Hygienically safe in use.
- Fully conforms to ISO 7376 and existing handles.
- Individually packed and labeled.
- In case of double polythene packing, reusable battery handle can be safe for use.
- Low profile shape of blades protects the patient from upper part of teeth.
Size numbers are not fully standardised between makers, so compare the size in millimetres when you replace blades from another brand. Our blade size guide explains the typical patient group for each size. The choice of blade is always a clinical decision.
Sizes in this range, 65mm to 205mm
Specifications
Technical details
From our catalogue, Premium Laryngoscope Range, Volume III.
Identification
| Product | Miller Blades, Fiber Optic Acrylic, Metallic ECO Line |
|---|---|
| Product code | AL-1804-E |
| Size codes | AL-1804-00E to AL-1804-4E |
| Blade numbers | 00 to 4 (6 sizes) |
| Sizes | 65mm to 205mm |
| Category | Fiber Optic Green System Disposable Blades |
| Pattern | Miller, straight blade |
| Construction | Metallic, ECO Line |
Light
| Light system | Fiber optic, green system: the light comes from the handle |
|---|---|
| Light guide | Acrylic (plastic) optical fiber; 5mm diameter in the range |
| Light source | In the handle (LED or xenon, depending on the handle) |
Material and use
| Material | Metallic: stainless steel spatula and aluminium heel (range) |
|---|---|
| Use | Single patient use only |
| Sterilisation | Supplied surgically cleaned; for single patient use, not for reprocessing |
| Latex | Latex free |
| Packing | Individually packed and labelled |
Standard and fit
| Standard | Conforms to ISO 7376 |
|---|---|
| Handle fit | Existing green-system handles made to ISO 7376 |
| Conventional handles | Not designed to fit (different fitting) |
Origin
| Manufacturer | Long Life Surgical Industries |
|---|---|
| Made in | Sialkot, Pakistan |
| Making laryngoscopes since | 1981 |
| Catalogue | Premium Laryngoscope Range, Volume III, page 24 |
Compatibility
Fits green-system handles
The blade conforms to ISO 7376, the international standard for laryngoscopes, and uses the fiber optic green-system fitting. It fits existing green-system handles made to ISO 7376: reusable handles or single-use handles, from us or from another maker.
It is not designed for conventional handles: a conventional blade carries a small lamp near its tip, while a green-system blade takes its light from a lamp or LED in the handle. Read ISO 7376 and the green system explained.
Green-system handles in our range
Battery Handles Fiber Optic LED, Semimetal with BatteriesAL-1851 · 3 sizes · See the handle
Battery Handles Fiber Optic LED, Metallic with BatteriesAL-1852 · 3 sizes · See the handle
Battery Handles Fiber Optic LED, Semimetal without BatteriesAL-1858 · 3 sizes · See the handle
Battery Handles Fiber Optic LED, Metallic without BatteriesAL-1859 · 3 sizes · See the handle
Battery Handles Fiber Optic LED, Stainless SteelAL-1453 · 5 sizes · See the handle
Battery Handles Fiber Optic LED, Brass Chrome PlatedAL-1454 · 5 sizes · See the handle
Battery Handles Fiber Optic Xenon, Stainless SteelAL-1451 · 5 sizes · See the handle
Battery Handles Fiber Optic Xenon, Brass Chrome PlatedAL-1452 · 5 sizes · See the handle
Spare part Replacement LampsAL-1455 · 4 codes · Spare part
LED or xenon? Compare the two light sources.
Single patient use
Open, use once, dispose
Single-use blades are supplied surgically cleaned and individually packed. Each blade is for one patient only. Always follow the instructions for use (IFU) and your hospital rules.
- 01Open the individual pack just before use.
- 02Attach the blade to a green-system handle and check the light before use.
- 03Use the blade for one patient only.
- 04After use, dispose of the blade following your hospital rules and the instructions for use (IFU). Do not clean, sterilise or reuse it.
Questions
Common questions about this blade
Which sizes of the Miller Blades, Fiber Optic Acrylic, Metallic ECO Line are available?
There are 6 sizes: size 00 (Premature, 65mm, code AL-1804-00E), size 0 (Neonate, 78mm, code AL-1804-0E), size 1 (Infant, 102mm, code AL-1804-1E), size 2 (Child, 154mm, code AL-1804-2E), size 3 (Medium Adult, 195mm, code AL-1804-3E), size 4 (Large Adult, 205mm, code AL-1804-4E).
Which Miller blade size is for a neonate, infant or child?
In the catalogue, the Miller Blades, Fiber Optic Acrylic, Metallic ECO Line has these sizes for babies and children: size 00 (Premature, 65mm, code AL-1804-00E), size 0 (Neonate, 78mm, code AL-1804-0E), size 1 (Infant, 102mm, code AL-1804-1E), size 2 (Child, 154mm, code AL-1804-2E). The adult sizes are size 3 (Medium Adult, 195mm, code AL-1804-3E), size 4 (Large Adult, 205mm, code AL-1804-4E). Choosing the size for a patient is a clinical decision. Our size chart compares every length on a millimetre ruler.
How long is each Miller blade size in millimetres?
In the Miller Blades, Fiber Optic Acrylic, Metallic ECO Line, size 00 is 65mm; size 0 is 78mm; size 1 is 102mm; size 2 is 154mm; size 3 is 195mm; size 4 is 205mm.
What is the Miller blade, fiber optic acrylic, metallic, ECO Line?
ECO Line single-use Miller laryngoscope blade for the fiber optic green system, in metallic construction: a straight stainless steel spatula with a metal heel, and an acrylic (plastic) optical fiber light guide. There is no lamp in the blade: the light comes from the green-system handle. Supplied surgically cleaned, individually packed and labelled, latex free. Conforms to ISO 7376 and fits existing green-system handles. 6 sizes, from size 00 Premature (65mm) to size 4 (205mm).
Which handles fit this blade?
It is a fiber optic green-system blade that conforms to ISO 7376, so it fits existing green-system handles made to ISO 7376, reusable or single-use. In our own range: Battery Handles Fiber Optic LED, Semimetal with Batteries, Battery Handles Fiber Optic LED, Metallic with Batteries, Battery Handles Fiber Optic LED, Semimetal without Batteries, Battery Handles Fiber Optic LED, Metallic without Batteries, Battery Handles Fiber Optic LED, Stainless Steel, Battery Handles Fiber Optic LED, Brass Chrome Plated, Battery Handles Fiber Optic Xenon, Stainless Steel, Battery Handles Fiber Optic Xenon, Brass Chrome Plated.
Does it fit a conventional laryngoscope handle?
No. Green-system (fiber optic) and conventional laryngoscopes use different fittings and light positions, so their blades and handles are not designed to work together. Use a green-system handle.
Can the blade be reused or sterilised?
No. It is for single patient use only. It is supplied surgically cleaned, individually packed and labelled. Dispose of it after use, following your hospital rules and the instructions for use (IFU).
Where is it made?
In our own factory in Sialkot, Pakistan. Long Life Surgical Industries has made laryngoscopes since 1981.
How do I get a price or samples?
Add it to your enquiry list, or send us the codes with quantities and your country. Our export team replies within one working day with prices and lead times. Evaluation samples are available on request.
Documents
For your file or tender
Sent with every quotation, and on request at any time.